Forensic Science International
Volume 199, Issue 1 , Pages 9-14, 15 June 2010

Accuracy and reliability of facial soft tissue depth measurements using cone beam computer tomography

  • Zacharias Fourie

      Affiliations

    • University Medical Center Groningen, University of Groningen, Department of Orthodontics, Hanzeplein 1, 9700 RB Groningen, The Netherlands
    • Corresponding Author InformationCorresponding author at: University Medical Center Groningen, University of Groningen, Department of Orthodontics, Hanzeplein 1, P.O. Box 30001, 9700 RB Groningen, The Netherlands. Tel.: +31 50 361 0092; fax: +31 50 361 9712.
  • ,
  • Janalt Damstra

      Affiliations

    • University Medical Center Groningen, University of Groningen, Department of Orthodontics, Hanzeplein 1, 9700 RB Groningen, The Netherlands
  • ,
  • Peter O. Gerrits

      Affiliations

    • University Medical Center Groningen, University of Groningen, Department of Anatomy, Hanzeplein 1, 9700 RB Groningen, The Netherlands
  • ,
  • Yijin Ren

      Affiliations

    • University Medical Center Groningen, University of Groningen, Department of Orthodontics, Hanzeplein 1, 9700 RB Groningen, The Netherlands

Received 20 September 2009; received in revised form 4 February 2010; accepted 15 February 2010. published online 17 March 2010.

Abstract 

It is important to have accurate and reliable measurements of soft tissue thickness for specific landmarks of the face and scalp when producing a facial reconstruction. In the past several methods have been created to measure facial soft tissue thickness (FSTT) in cadavers and in the living. The conventional spiral CT is mostly used to determine the FSTT but is associated with high radiation doses. The cone beam CT (CBCT) is a relatively new computer tomography system that focuses on head and neck regions and has much lower radiation doses. The aim of this study is to determine the accuracy and reliability of CBCT scans to measure the soft tissue thicknesses of the face. Seven cadaver heads were used. Eleven soft tissue landmarks were identified on each head and a punch hole was made on each landmark using a dermal biopsy punch. The seven cadaver heads were scanned in the CBCT with 0.3 and 0.4mm resolution. The FSTT at the 11 different sites (soft tissue landmarks) were measured using SimPlant-ortho volumetric software. These measurements were compared to the physical measurements. Statistical analysis for the reliability was done by means of the interclass coefficient (ICC) and the accuracy by means of the absolute error (AE) and absolute percentage error (APE). The intra-observer (0.976–0.999) and inter-observer (0.982–0.997) correlations of the CBCT and physical measurements were very high. There was no clinical significant difference between the measurements made on the CBCT images and the physical measurements. Increasing the voxel size from 0.4 to 0.3mm resulted in a slight increase of accuracy. Cone beam CT images of the face using routine scanning protocols are reliable for measuring soft tissue thickness in the facial region and give a good representation of the facial soft tissues. For more accurate data collection the 0.3mm voxel size should be considered.

Keywords: Soft tissue, Cone beam CT, Tissue depth measurements, Cadaver

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0379-0738(10)00074-5

doi:10.1016/j.forsciint.2010.02.018

Forensic Science International
Volume 199, Issue 1 , Pages 9-14, 15 June 2010